Difference between revisions of "Vacuum Former"

From maker-hub
Jump to navigation Jump to search
Line 86: Line 86:
  
 
==Troubleshooting==
 
==Troubleshooting==
If belts have hole or tears they need to be replaced.
+
Make sure to put draft on your form to prevent sticking.  
Burnt discs need to be replaced.
+
If the plastic is not hot enough it won't pull down over the form.
  
 
==Maintenance==
 
==Maintenance==

Revision as of 17:21, 19 June 2020

Vacuum Former.png
Formech.jpg

Make: Formech

Model: 508DT

Ace: Needed (Makerhub@georgefox.edu).

Location: The Vault

Description

The Formech 508DT Vacuum Former is a plastic molding machine that utilizes heat and a vacuum to stretch heated plastic over a mold. The vacuum former is great for thin plastic molds, although there are some limitations on the shape and size. The max dimensions for the mold are 17”x19” with a depth of 7.3". The max thickness for the plastic sheet is 0.25" Molds can be made from many types of materials. It's fairly common to see molds made from wood. Molds need to have some draft so they can be removed from the plastic.


Here is an example of this piece of equipment being used.

Documentation

Terminology

  • Table- The bed that the mold rests on.
  • Clamp Frame-
  • Toggle Clamp Screws-
  • Draft-

Knowing what the different buttons in the touchscreen operation mean is important in operating the vacuum former. The three primary ones are heat , vacuum , and release . For a full list, refer to the manual.


Manual Media:Manual-508DT.pdf

Training

Overview

The vacuum former can mold up to a 19"x17" square and to a depth of 7.3".

Molds must slant outwardly slightly to ensure that they can be popped out of the plastic after molding is finished.

Demonstration

You will need to demonstrate the safe setup and use of the belt/disc sander. You will be sketching an arc onto a piece of scrap material and sanding up to the line using the disc and belt. Make sure to keep the material moving to prevent burning and tearing of the sanding belt/disc.

Operation

Formech Controls.JPG

Operation

  • Place a mold into the tray and lower it.
  • Mold cannot be concave and must slant outwards slightly or it will not be removable from the plastic.
  • Place plastic into the clamps ensuring it completely covers the white seals.
  • Turn on the heaters. They should take about 15 minutes to warm up.
  • Lift the table.
  • Turn on the vacuum.
  • Let the plastic cool, then hit the release button.
  • Lower the table to remove the plastic.
  • Reset the table.

Safety

  • Parts of the machine can reach over 300 degrees C. Don't touch the heater or heat shield surrounding the heater.
  • Never put your hand in a position it could be pinched by the molding frame.
  • The formed plastic is very hot and sticky. It could stick to you and continue to burn if you touch it.
  • Some types of plastics could give off toxic fumes when heated. Check the SDS before working with materials you are unfamiliar with.

Certification

Foxtale Course

Troubleshooting

Make sure to put draft on your form to prevent sticking. If the plastic is not hot enough it won't pull down over the form.

Maintenance

General maintenance

The following items need to be periodically lubricated:

  • Idler slide (use non hardening grease)
  • Table trunnion (use non hardening grease)

Specific Maintenance Tasks

Maintenance Procedure Frequency Done By
Replace sanding Belt/Pad As Needed Ace/Tech