Line 106: |
Line 106: |
| # ''Priming the Conductor'' | | # ''Priming the Conductor'' |
| ## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch. | | ## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch. |
− | ## '''EXPLAIN THIS AWFUL PROCESS. TALK ABOUT NOZZLES BREAKING''' [[File:Voltera priming.jpg|border|none|300x300px]] <br /> | + | ## '''Read carefully.''' The Voltera application explains this next step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings: |
| + | ## [[File:Voltera priming.jpg|border|none|300x300px]] <br /> |
| ## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br /> | | ## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br /> |
| # ''Calibration'' | | # ''Calibration'' |
Line 113: |
Line 114: |
| ## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br /> | | ## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br /> |
| ## The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]] <br /> | | ## The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]] <br /> |
− | ## In this case, to make an adjustment, the ink height was set to a Z of 0.09 mm and the flow was set to an E of -10 um. | + | ## In this case, to make an adjustment, the ink height was set to a '''Z of 0.09 mm''' and the flow was set to an '''E of -10 um.''' |
| ## '''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!''' | | ## '''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!''' |
| ## If an adjustment was made, '''wipe the board clean with a paper towel (shown below)''' and repeat step 9. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]] <br /> | | ## If an adjustment was made, '''wipe the board clean with a paper towel (shown below)''' and repeat step 9. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]] <br /> |