Changes

Jump to navigation Jump to search
Line 106: Line 106:  
# ''Priming the Conductor''
 
# ''Priming the Conductor''
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
## '''EXPLAIN THIS AWFUL PROCESS. TALK ABOUT NOZZLES BREAKING''' [[File:Voltera priming.jpg|border|none|300x300px]] <br />
+
## '''Read carefully.''' The Voltera application explains this next step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings:
 +
##  [[File:Voltera priming.jpg|border|none|300x300px]] <br />
 
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
 
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
 
# ''Calibration''
 
# ''Calibration''
Line 113: Line 114:  
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br />
 
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br />
 
## The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]] <br />
 
## The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]] <br />
## In this case, to make an adjustment, the ink height was set to a Z of 0.09 mm and the flow was set to an E of -10 um.  
+
## In this case, to make an adjustment, the ink height was set to a '''Z of 0.09 mm''' and the flow was set to an '''E of -10 um.'''
 
## '''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!'''
 
## '''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!'''
 
## If an adjustment was made, '''wipe the board clean with a paper towel (shown below)''' and repeat step 9. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]] <br />
 
## If an adjustment was made, '''wipe the board clean with a paper towel (shown below)''' and repeat step 9. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]] <br />
1,341

edits

Navigation menu