## '''You MUST ensure the outline does not collide with the clamps AND does not exceed the dimensions of the board!''' Do NOT proceed until this is checked!
 
## '''You MUST ensure the outline does not collide with the clamps AND does not exceed the dimensions of the board!''' Do NOT proceed until this is checked!
 
## Click "Next."
 
## Click "Next."
## Click "Probe" and wait for the Voltera to finish its measurements.
+
## Click "Probe" and wait for the Voltera to finish its measurements. [[File:Voltera mount_probing.jpg|border|none|300x300px]] <br />
 
## Click "Next."
 
## Click "Next."
 
## Remove the probe, replace the cap, place the probe back in the drawer, and click "Next."
 
## Remove the probe, replace the cap, place the probe back in the drawer, and click "Next."
 
# ''Priming the Conductor''
 
# ''Priming the Conductor''
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
## '''EXPLAIN THIS AWFUL PROCESS. TALK ABOUT NOZZLES BREAKING'''
+
## '''EXPLAIN THIS AWFUL PROCESS. TALK ABOUT NOZZLES BREAKING''' [[File:Voltera priming.jpg|border|none|300x300px]] <br />
## Mount the dispenser.
+
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
 
# ''Calibration''
 
# ''Calibration''
 
## Click "Advanced." Start with the Z at 0.10 mm and the E at 0 um. Adjust the Voltera to these values.
 
## Click "Advanced." Start with the Z at 0.10 mm and the E at 0 um. Adjust the Voltera to these values.
 
## Click "Calibrate."
 
## Click "Calibrate."
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink.
+
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera printing.jpg|border|none|300x300px]] <br />
 
## Fig. 1 has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up.
 
## Fig. 1 has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up.
 
## In this case, to make an adjustment, the ink height was set to a Z of 0.09 mm and the flow was set to an E of -10 um.  
 
## In this case, to make an adjustment, the ink height was set to a Z of 0.09 mm and the flow was set to an E of -10 um.  