* Turn on the heaters and set the temperature. The temperature should be 80-120 degrees Celsius.
* Turn on the heaters and set the temperature. The temperature should be 80-120 degrees Celsius.
* The heaters should take about 15 minutes to warm up.
* The heaters should take about 15 minutes to warm up.
+
* After 15 minutes roll the heater over the plastic
+
* Allow the heater to sit over the plastic for 90 seconds if the plastic is 1.8mm thick or 180 seconds if the plastic is 3.3mm thick.
+
* DO NOT OVERHEAT PLASTIC! this will cause the plastic to develop webbing after the vacuum which will ruin the mold.
* Lift the table.
* Lift the table.
* Turn on the vacuum.
* Turn on the vacuum.