Difference between revisions of "PCB Printer"

From maker-hub
Jump to navigation Jump to search
 
(86 intermediate revisions by 11 users not shown)
Line 1: Line 1:
[[File:PCB printer icon.png|left|frameless|100x100px]]
+
{{#set:
Make: {{#show: {{PAGENAME}} |?Has make}}
+
|Is equipment=True
 +
|Is located in facility=PCB Lab
 +
|Is used in domain=Electronics
 +
|Has name={{PAGENAME}}
 +
|Has make=Voltera
 +
|Has model=V-One
 +
|Has serial number=V1-05-0129-120 / V1-04-0183-120
 +
|Has life expectancy=
 +
|Has year of manufacture or purchase=
 +
|Has replacement cost=
 +
|Has icon=File:PCB_printer_icon.png
 +
|Has icondesc=Voltera Icon
 +
|Has iconwname=File:PCB_printer_icon_name.png
 +
|Has image=File:voltera-vone.png
 +
|Has imagedesc=The Voltera V-One PCB Printer
 +
|Has description=
 +
|Has certification=https://georgefox.instructure.com/courses/1288
 +
|Has group=Circuit Board Design
 +
|Has ace=Isaac Beals;ibeals16@georgefox.edu
 +
}}
 +
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|140px|left|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
 +
[[{{#show: {{FULLPAGENAME}}|?Has image|link=none}}|300px|thumb|upright=1.5|{{#show: {{FULLPAGENAME}}|?Has imagedesc}}]]Make: {{#show: {{PAGENAME}} |?Has make}}
  
 
Model: {{#show: {{PAGENAME}} |?Has model}}
 
Model: {{#show: {{PAGENAME}} |?Has model}}
 +
 +
Serial Number: {{#show: {{PAGENAME}} |?Has serial number}}
  
 
Ace: {{#show: {{PAGENAME}} |?Has ace.Has name}} ({{#show: {{PAGENAME}} |?Has ace.Has email address}}).
 
Ace: {{#show: {{PAGENAME}} |?Has ace.Has name}} ({{#show: {{PAGENAME}} |?Has ace.Has email address}}).
Line 8: Line 31:
 
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
 
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
  
 +
 +
 +
__TOC__
 
==Description==
 
==Description==
  
Insert Description Text
+
The PCB Printer (Voltera V-One) brings quick turn PCBs to your desktop. Import your Gerber file into the Voltera software, press print, and the V-One will bring your board to life. Use the drilling, solder paste dispensing, and reflow features to mount components onto your printed board, or mount components on a pre-fabricated board with ease.
  
Here is an example of this piece of equipment being used.
+
This is a simple example of what the PCB Printer can do. Currently the PCB lab has a different baking process using a different oven, so we will be curing the boards using a different method than shown in the video.  
  
Insert video media here.
+
{{#evu:https://www.youtube.com/watch?v=N6nEgN4THRE}}
  
 
==Documentation==
 
==Documentation==
Line 20: Line 46:
 
====Terminology====
 
====Terminology====
  
Insert terminology here
+
The following conductive inks and pastes are stocked in the PCB Lab.  Each material requires a special heating program setting. See each individual material below for the proper reflow oven setting.
  
User Manual
+
Inks are also identified by a lot name and expiration date. If properly installed, the expiration date should be viewable through the window in the dispenser, but the lot name will not. Refer to the label on the back of the dispenser for the lot name. When selecting the ink you're using in the Voltera software, it will identify the ink by type, lot name, and expiration date. Make sure you select the correct one.
  
==Training==
+
[[File:voltera_aqueous.PNG|frameless|left|200px]]
====Overview====
+
'''Conductive Ink'''
  
Insert Text
+
- Use to lay conductive traces on substrates (Green is "V1 Ink" setting on Reflow Oven)
 +
<br /><br /><br />
  
====Demonstration====
+
[[File:voltera_furious.PNG|frameless|left|200px]]
 +
'''Solder Paste'''
  
Insert text
+
- Use only on boards that utilize Voltera's ink traces, such as the ink above. (Orange is "V1 Paste" setting on Reflow Oven)
 +
<br /><br /><br />
  
====General Procedure====
+
[[File:voltera_armored.PNG|frameless|left|200px]]
 +
'''Solder Paste Sn63 Pb37'''
  
Insert text
+
- Use only premade boards, such as ones from [https://jlcpcb.com/ JLCPCB] (Blue is "Sn63Pb37" on Reflow Oven)
  
==Safety==
+
<br />
Insert text
+
<br />
  
==Certification==
+
<gallery>
 
+
File:Voltera substrates.jpg|Substrates
Foxtale Quiz
+
File:Vone probe.jpg|Probe
 
+
File:Dispenser and Sheath.jpg|Dispenser and Sheath
==Troubleshooting==
+
File:Voltera conductive ink.png|Conductive Ink Cartridge
 
+
File:Voltera 225 nozzle.jpg|Nozzle - 225 Micron
==Maintenance==
+
File:Voltera burnish.jpg|Burnishing Pads
====General maintenance====
+
</gallery>
 
 
Insert text
 
 
 
====Specific Maintenance Tasks====
 
{| class="wikitable"
 
!Maintenance Procedure
 
!Frequency
 
!Done By
 
|-
 
|Sample
 
|Sample
 
|Sample
 
|}
 
{{#set:
 
|Is equipment=True
 
|Is located in facility=PCB Lab
 
|Is used in domain=Electronics
 
|Has name={{PAGENAME}}
 
|Has icon=File:PCB_printer_icon.png
 
|Has icondesc=Voltera Icon
 
|Has iconwname=File:PCB_printer_icon_name.png
 
|Has image=File:voltera-vone.png
 
|Has imagedesc=The Voltera V-One PCB Printer
 
|Has description=
 
|Has certification=
 
|Has model=V-One
 
|Has group=Circuit Board Design
 
|Has make=Voltera
 
|Has ace=Jake Whipple; jwhipple15@georgefox.edu
 
}}
 
  
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|100px|left|top|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
+
[[Media:Voltera V-One Manual English.pdf|Voltera User Manual]]
[[{{#show: {{FULLPAGENAME}}|?Has image|link=none}}|300px|thumb|upright=1.5|{{#show: {{FULLPAGENAME}}|?Has imagedesc}}]]
 
The Voltera V-One brings quick turn PCBs to your desktop. Import your gerber file into the Voltera software, press print, and the V-One will bring your board to life. Use the solder paste dispensing and reflow features to mount components onto your printed board, or mount components on a pre-fabricated board with ease. <ref>Description taken from [https://www.elektor.com/voltera-v-one Elektor].</ref>
 
  
The current Ace of the {{PAGENAME}} is '''{{#show: {{PAGENAME}} |?Has ace.Has name}}''' ({{#show: {{PAGENAME}} |?Has ace.Has email address}}).<br /><br />
+
[https://support.voltera.io/circuit-design-guidelines Circuit Design Guidelines]
__TOC__
 
  
== Documentation ==
+
[https://support.voltera.io/altium#main Altium Gerber Export Guide]
  
* [https://www.voltera.io/ Voltera Home Page]
+
[https://www.voltera.io/ Voltera Home Page]
* [https://www.voltera.io/docs/downloads/manuals/Voltera%20V-One%20Manual%20%5BEnglish%5D.pdf User Manual]
 
* [https://support.voltera.io/hc/en-us/sections/115001325748-User-Guides User Guides]
 
  
== Current Inks and Paste ==
+
[https://support.voltera.io/hc/en-us/sections/115001325748-User-Guides User Guides]
The following conductive inks and pastes are stocked in the PCB Lab.
 
  
[[File:voltera_aqueous.PNG|frameless|left|200px]]
+
==Before you Print==
'''Conductive Ink:''' ''AqueousSnake''
 
  
- Use to lay conductive traces on substrates
+
Here are a few things to check before exporting your gerber files and fabricating your PCB. [[File:Voltera-drillbits.png|thumb|300x300px|right|Available drill bit sizes]]
<br /><br /><br />
 
  
[[File:voltera_furious.PNG|frameless|left|200px]]
+
#Verify via hole sizes.
'''Solder Paste:''' ''FuriousAnt''
+
##Based on the size of what needs to go in the via, select a rivet with the proper internal diameter from the table on the [[Through Hole Press]] page.
 +
##Once you've selected the rivet size, take the outer diameter of the rivet from the table and add 0.1mm.
 +
##Check this outer diameter against the available drill sizes for the Voltera (see the image to the right). Round up to the nearest drill size and use that for the hole size in Altium.
 +
#Verify annular ring size
 +
##Your annular rings (via diameter) should be at least as large as the head diameter of the rivets you plan to use, otherwise they might not make good contact.
 +
#Check that your design follows the circuit design guidelines at the link above
  
- Use only on boards that utilize Voltera's ink traces, such as the ink above.
+
==Training==
<br /><br /><br />
+
====Operation====
  
[[File:voltera_armored.PNG|frameless|left|200px]]
+
The PCB Printer is a fantastic tool for prototyping PCBs. After uploading Gerber files from Altium or a related software, the Voltera will be able to print traces and pads. The Voltera has the ability to bake traces and reflow components on its heated bed, but you will need to use the reflow oven to bake boards. The PCB Lab uses the reflow oven for baking due to the amount of people it needs to accommodate, so users will only be using the PCB Printer to print traces and pads. The Conductive Ink (used for Traces) is indicated by a green dot on the dispenser, the Voltera Solder Paste (used for Pads) is indicated by an orange dot on the dispenser, and the Manufactured Solder Paste (used for Pads) is indicated by a blue dot on the dispenser.
'''Solder Paste Sn63 Pb37:''' ''ArmoredArmadillo''
 
  
- Use only premade boards, such as ones from [https://www.sunstone.com/ Sunstone Circuits]
+
Before beginning with your PCB, it is imperative that it is completely flat, meaning no components are installed, as it will result in breaking the nozzle of the dispenser, or it will be unable to calibrate correctly.
<br /><br /><br />
 
  
== Terminology ==
+
====Demonstration====
The Voltera utilizes many pieces of equipment. It is important to be able to distinguish them, especially when trying to explain troubleshooting issues. Here are the items you should familiarize yourself with:
 
  
<gallery>
+
To show a complete knowledge of the PCB Printer, the student will design a PCB in Altium or related software, print the traces/pads, and transition to the Reflow Oven. As a part of the process, the student will also perform correct set up and shut down procedures, all of which can be found in the General Procedure below.
File:voltera_substrates.jpg|Substrates
 
File:vone_probe.jpg|Probe
 
File:Dispenser_and_Sheath.jpg|Dispenser and Sheath
 
File:voltera_conductive_ink.png|Conductive Ink Cartridge
 
File:voltera_225_nozzle.jpg|Nozzle - 225 Micron
 
File:voltera_burnish.jpg|Burnishing Pads
 
</gallery>
 
  
 +
====General Procedure====
  
(Pictures to add)
+
Using the Voltera to create single-sided boards with NO vias or holes.[[File:voltera_blinky_500.jpg|300x300px|thumb|right|Training board - The Blinky 500]]
Sacrificial layer
 
 
 
== Training ==
 
 
 
=== Level 1 ===
 
[[File:voltera_blinky_500.jpg|300x300px|thumb|right|Training board - The Blinky 500]] Successful completion of level 1 training will grant access to:
 
* Using the Voltera to create single-sided boards with NO vias or holes.
 
 
 
  
# ''Ready the Ink''
+
#'''Drilling'''
## Reference the [[#Current Inks and Paste|Current Inks and Paste]] for information on the what the PCB lab is currently stocked with.
+
##'''This board in particular does not have any holes, so this entire step can be skipped for this procedure''', however, these are the steps to take if you need to drill holes in the future.
## Grab the correct conductive ink from the fridge. It is labeled with a '''green''' sticker.
+
##After opening the Voltera software, select Drill. This option is chosen only if you want to add holes to an existing board.
## Set the conductive ink on the table, allowing to begin to warm to room temperature. <br /><br />
+
##For Drilling, you can either choose the Simple or Aligned route. Choose Simple if your board has no existing features, and choose Aligned if your board has some existing features. Lets go through the process for both.
# ''Software Setup''
+
##Drilling for a Simple Board
## Download the files for this project [[Media:pcb_printer_level_1.zip|here]].
+
###Alrighty, you've chosen Simple, so this procedure assumes there is absolutely nothing fabricated on the board. Not gonna lie, this procedure is a little more sketchy than aligned simply because you literally eyeball your board's outline. The no eloquent calibration system. That's just how it works.
## Power on the Voltera.
+
###Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
## Open the Voltera Windows application.
+
###Then it will ask you to move your boards location on the plate so the Voltera knows where it needs to drill. This is the sketchy part. It outlines a square, and you make a judgement based on what it thinks. If it outlines too low, move your circuit up further on the plate to compensate for it. If it outlines too far to the left, move your circuit to the right on the plate to compensate for it. Continue this process until it looks "good enough."
## Select "Print" and then "Simple."
+
###Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication... [[File:Board.jpg|none|thumb|300x300px]]
## Add the proper conductive ink. This is the same conductive ink you acquired in step 1.3.
+
###Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
## Load the ink file from the project files. This is the Top Layer Gerber file.  
+
###Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient. The transition between printing and drilling is done with the same alignment.
## Click "Next." <br /><br />
+
###Once that is complete, it is time to select the holes we want to drill. '''All the holes you select are highlighted in Green.''' Remove the probe and select which holes you want to drill. Remember not to drill the holes that already exist![[File:...holes.png|none|thumb|300x300px]]
# ''Cleaning the Sensors''
+
###Select the corresponding drill bit, put it into the drill, mount it, and plug it in. Be extra careful not to break anything. People usually break it because while they are mounting it, the drill hits the Voltera and snaps. It's okay to push it into the drill pretty far, and this will keep you from breaking it. '''DON'T FORGET TO USE THE ALLEN WRENCH TO SECURE THE BIT!'''
## Take a cue tip and dip it into the isopropyl alcohol. The cue tip should be moist, but NOT soaked. Dab the cue tip on a paper towel to dry it slightly.
+
###The drill should sing you a little song once it's connected. '''Before drilling, prepare the vacuum.''' Use this to suck all the debris that comes from your board. You can get it decently close to the board, even on the board while it is drilling, just be sure to move when the drill is getting ready to move.[[File:VacuumBoi.jpg|none|thumb]]
## Clean the calibration switches by rubbing them with the cue tip. [[File:Voltera cleaning.jpg|border|none|300x300px|Cleaning the calibration switches]] <br />
+
###And you're finished drilling holes! Vacuum up any debris and continue with laying the traces.
## Click "Next." <br /><br />
+
##Drilling for an Aligned Board
# ''Clamping the Substrate''
+
###Awesome, you've chosen Aligned, so this procedure assumes you have some preexisting holes and the like on the board.
## Acquire a 1.5" by 2" blank board. They are located in the one of the drawers.
+
###Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
## Slide the board underneath the clamps on the Voltera, push the clamps towards each other, and finger-tighten the thumb screws. [[File:Voltera clamping.jpg|border|none|300x300px]] <br />
+
###Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication...[[File:Board.jpg|none|thumb|300x300px]]
## Click "Next."  <br /><br />
+
###Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
# ''Mounting the Probe''
+
###Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient.
## Pull the probe from one of the drawers. [[File:Voltera drawer.jpg|border|none|300x300px]] <br />
+
###Once that is complete, it is time to select the holes we want to drill. '''All the holes you select are highlighted in Green. Anything that is highlighted in Green will be executed.''' Remove the probe and select which holes you want to drill. Remember not to drill the holes that already exist![[File:...holes.png|none|thumb|300x300px]]
## Remove the cap and place it near the Voltera.
+
###Select the corresponding drill bit, put it into the drill, mount it, and plug it in. Be extra careful not to break anything. People usually break it because while they are mounting it, the drill hits the Voltera and snaps. It's okay to push it into the drill pretty far, and this will keep you from breaking it. '''DON'T FORGET TO USE THE ALLEN WRENCH TO SECURE THE BIT!'''
## Mount the probe onto the magnetic gantry. It should snap into place and the contacts should align. [[File:Voltera mount_probe.jpg|border|none|300x300px]] <br />
+
###The drill should sing you a little song once it's connected. '''Before drilling, prepare the vacuum.''' Use this to suck all the debris that comes from your board. You can get it decently close to the board, even on the board while it is drilling, just be sure to move when the drill is getting ready to move.[[File:VacuumBoi.jpg|none|thumb]]
## Click "Next."  <br /><br />
+
###And you're finished drilling holes! Vacuum up any debris and continue with laying the traces.
# ''Positioning and Probing''
+
#'''Ready the Ink'''
## Click "Outline." This will show you where the Voltera thinks the board is. It will move the probe around the printer surface.
+
##The ink is most usable when it reaches room temperature, so we have to let it warm up in advance.
## Repeat step one until the outline is centered with the board. Click and drag the circuit in the Voltera application to move the outline.  
+
##Grab the correct conductive ink from the fridge, and let it warm up to room temperature, about 15-30 minutes. It is labeled with a '''green''' sticker.
## '''You MUST ensure the outline does not collide with the clamps AND does not exceed the dimensions of the board!''' Do NOT proceed until this is checked!
+
#'''Software Setup'''
## Click "Next."
+
##Download the files for this project [[Media:Pcb printer level 1.zip|here]].
## Click "Probe" and wait for the Voltera to finish its measurements. [[File:Voltera probing.jpg|border|none|300x300px]] <br />
+
##Power on the Voltera.
## Click "Next."
+
##Open the Voltera Windows application.
## Remove the probe, replace the cap, place the probe back in the drawer, and click "Next."  <br /><br />
+
##Select "Print" and then "Simple." "Print" indicates that we want to print traces, and "Simple" indicates that the board is not pre-fabricated. If we had a pre-fabricated board, we would instead select "Aligned" so we can align the holes.
# ''Priming the Conductor''
+
##Next we need to add the proper conductive ink, which is the same conductive ink you acquired in step 1.2.
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
+
##Load the ink file from the project files. This is the Top Layer Gerber file.
## '''Read carefully.''' The Voltera application explains this step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings: <br /><br /> - '''Nozzles are fragile!''' You would be surprised how easy it is to break one. Treat this process with care!<br /> - Hold the dispenser over a paper towel to prevent ink from getting everywhere.<br /> - If you need to wipe the nozzle, do so '''gently''' and '''use a cotton swab found in the drawers.''' <br /> - Ink should not be flowing quickly out of the dispenser when you finish priming, but '''a very small amount''' of flow is OK. <br /><br /> [[File:Voltera priming.jpg|border|none|300x300px]] <br />
+
#'''Clamping the Substrate'''
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
+
##Acquire a 1.5" by 2" blank board. They are located in the one of the drawers.
# ''Calibration''
+
##Slide the board underneath the clamps on the Voltera, push the clamps towards each other, and finger-tighten the thumb screws. You should not be able to move the board once you clamp them down. [[File:Voltera clamping.jpg|border|none|300x300px]]
## Click "Advanced." Start with the '''Z at 0.10 mm''' and the '''E at 0 um'''. Adjust the Voltera to these values.
+
#'''Mounting the Probe'''
## Click "Calibrate."
+
##Pull the probe from one of the drawers. The probe should have a large metal tip, do not confuse it with the dispenser. [[File:Voltera drawer.jpg|border|none|300x300px]]
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br />
+
##Remove the cap and place it near the Voltera.
## The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]] <br />
+
##Mount the probe onto the magnetic gantry. It should snap into place and the contacts should align. [[File:Voltera mount_probe.jpg|border|none|300x300px]]
## In this case, to make an adjustment, the ink height was set to a '''Z of 0.09 mm''' and the flow was set to an '''E of -10 um.'''  
+
#'''Positioning and Probing'''
## '''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!'''
+
##Click "Outline." This will show you where the Voltera thinks the board is. It will move the probe around the printer surface and determine how close the dispenser will need to be to the board.
## If an adjustment was made, '''wipe the board clean with a paper towel (shown below)''' and repeat step 9. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]] <br />
+
##Repeat step one until the outline is centered with the board. Click and drag the circuit in the Voltera application to move the outline.
## The example below is a more acceptable test print. Strive for this consistency. If your board looks right, proceed. [[File:Voltera calibrate_better.jpg|border|none|300x300px]] <br />
+
##'''You MUST ensure the outline does not collide with the clamps AND does not exceed the dimensions of the board!''' Do NOT proceed until this is checked!
## Click "Next."
+
##In the next step, Click "Probe" and wait for the Voltera to finish its measurements. [[File:Voltera probing.jpg|border|none|300x300px]]
## Wipe the board clean a final time.
+
##Remove the probe, replace the cap, place the probe back in the drawer, and proceed. <br /><br />
## Click "Next." <br /><br />
+
#'''Priming the Conductor'''
# ''Top Layer Print''
+
##Ensure 15 minutes have passed before beginning the next step. This helps the ink flow easier, so the dispenser should not be cold to the touch.
## The Voltera will print what is selected in green. Below is an example of a portion of the board selected. Ensure the portion you want to print is selected (in this case, select everything.) Remember that blue lines will not be printed. [[File:voltera_selection.PNG|300x300px|none]] <br />
+
##'''Read carefully.''' The Voltera application explains this step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings:<br /> - '''Nozzles are fragile!''' You would be surprised how easy it is to break one. Treat this process with care!<br /> - Hold the dispenser over a paper towel to prevent ink from getting everywhere.<br /> - If you need to wipe the nozzle, do so '''gently''' and '''use a cotton swab found in the drawers.''' <br /> - Ink should not be flowing quickly out of the dispenser when you finish priming, but '''a very small amount''' of flow is OK. <br /> [[File:Voltera priming.jpg|border|none|300x300px]]
## Click "Start." Let the Voltera finish its process. If a portion of the print fails or is incorrect, you can stop mid-print, or wait until it is finished and redo that selection. Also shown below is an example of a portion of ink that globbed up. The portion was wiped and can be reprinted. [[File:voltera_printing.jpg|300x300px|none]] <br /> [[File:voltera_print_blob.jpg|300x300px|none]] <br /> [[File:voltera_print_redo.jpg|300x300px|none]] <br />
+
##Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]]
## Remove the conductor, replace the cap, '''and return the conductive ink to the fridge!'''
+
#'''Calibration'''
## When you reach the "Flip Board," you are done. Quit the Voltera application.
+
##Click "Advanced." Start with the '''Z at 0.10 mm''' and the '''E at 0 um'''. Adjust the Voltera to these values, as it is a safe distance for the dispenser.
## Unclamp the board from the Voltera. Remember that the traces are still wet.<br /> <br />
+
##Click "Calibrate." The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink.[[File:Voltera calibrate.jpg|border|none|300x300px]]
# ''Baking the Traces''
+
##The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up. [[File:Voltera calibrate_bad.jpg|border|none|300x300px]]
## Switch over to the Reflow Oven. [[File:bake_go_2.jpg|300x300px|none]] <br />
+
##In this case, to make an adjustment, the ink height was set to a '''Z of 0.09 mm''' and the flow was set to an '''E of -10 um.''' This dispenses less ink than before.
## Power the Reflow Oven on.
+
##'''You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!'''
## Select "V1 INK." [[File:bake_ink_selection.jpg|300x300px|none]] <br />
+
##If an adjustment was made, '''wipe the board clean with a paper towel (shown below) and/or clean it with isopropyl alcohol''' and repeat the calibration. [[File:Voltera calibrate_wipe.jpg|border|none|300x300px]]
## The oven will warm up. When its ready, press "Enter" to open the tray.
+
##The example below is a more acceptable test print. Strive for this consistency. If your board looks right, proceed. [[File:Voltera calibrate_better.jpg|border|none|300x300px]]
## '''DANGER: The rails could be HOT! Take caution.''' Place the board securely on the rails. [[File:bake_place.jpg|300x300px|none]] <br />
+
##Click "Next," and wipe the board clean a final time, as you are now preparing to print your whole circuit. <br /><br />
## Press "Enter" to close the tray. [[File:bake_go.jpg|300x300px|none]] <br />
+
#'''Top Layer Print'''
## The preheat will take 2 minutes. The baking process takes about 30 min. [[File:bake_inside.jpg|300x300px|none]] <br />
+
##'''The Voltera will print what is selected in Green.''' Below is an example of a portion of the board selected. Ensure the portion you want to print is selected (in this case, select everything.) '''Remember that blue lines will not be printed.''' [[File:voltera_selection.PNG|300x300px|none]]
## The drawer will automatically open to initiate the cool down phase. '''DO NOT remove the board until the oven says all the stages are complete. DANGER: The rails are HOT!'''
+
##Click "Start." Let the Voltera finish its process. If a portion of the print fails or is incorrect, you can stop mid-print, or wait until it is finished and redo that selection. Also shown below is an example of a portion of ink that globbed up. The portion was wiped and can be reprinted. [[File:voltera_printing.jpg|300x300px|none]] <br /> [[File:voltera_print_blob.jpg|300x300px|none]] <br /> [[File:voltera_print_redo.jpg|300x300px|none]] <br />
## When cool down is complete, remove the board from the oven. <br /> <br />
+
##Remove the conductive ink, put the cap back on, '''and return the conductive ink to the fridge!'''
#''Preparing for Solder Paste''
+
##When you reach the instruction titled "Flip Board," you are done. We want to bake these traces on the Reflow Oven before we do anything else to the board.
##Take a burnishing pad from one of the drawers.
+
##Unclamp the board from the Voltera, and remember that the traces are still wet, so do not smear them around.
##Rub the substrate with the pad until the traces have a shine to them, rather than a dull appearance.
+
##Consult the Reflow Oven wiki and complete that process. Bake the board soon after printing to ensure best results.
##Replace the burnishing pad back into the drawer <br /> <br />
+
#'''Preparing for Solder Paste'''
#''Aligning the Paste''
+
##You should now have a PCB with traces baked on it! Time to make those pads for placing components.
##At this time, retrieve the solder paste from the fridge and set it out to warm. The correct paste is labeled with a '''orange''' sticker.
+
##Take a burnishing pad from one of the drawers. Rub the substrate with the pad until the traces have a shine to them, rather than a dull appearance. This cleans the surface of the traces and makes them look super shiny. '''AND IT IS CRITICALLY IMPORTANT!!! IF YOU DO NOT DO THIS, THE SOLDER HAS A VERY DIFFICULT TIME STICKING!!!!'''
##Take the board back to the Voltera.
+
##Replace the burnishing pad back into the drawer.
##Clamp the board into place.
+
#'''Aligning the Paste'''
##Open the Voltera application and choose "Solder."
+
##This process will help the Voltera know where it needs to print solder. The user gives it two locations where the pads should go, and the Voltera can use the Gerber files to determine where else pads need to go.
##Choose the proper paste. In this case you want the orange-labeled paste.
+
##At this time, retrieve the solder paste from the fridge and set it out to warm. The correct paste is labeled with an '''orange''' sticker.
##Clean the calibration switches.
+
##Take the board back to the Voltera and clamp the board into place. Again, you should not be able to move the board after it is clamped.
##Mount the probe. Click "Next."
+
##Open the Voltera application and choose "Solder," and choose the proper paste. In this case you want the '''orange'''-labeled paste.
##Click 'Move to feature." This will move the probe to a pre-determined feature. It will not be aligned properly.
+
##Clean the calibration switches, mount the probe, and proceed.
##First, use the arrow keys to roughly align the feature with the probe.
+
##Click 'Move to feature." This will move the probe to a pre-determined feature and should not be aligned properly on the first go. It is your job to align it correctly.
 +
##First, use the arrow keys to roughly align the feature with the probe. This process will help the Voltera know where it needs to put the pads.
 
##Next, click "Lower," and use the arrow keys to fine-tune the alignment. Your precision in these steps is key to getting solder paste in the correct places.
 
##Next, click "Lower," and use the arrow keys to fine-tune the alignment. Your precision in these steps is key to getting solder paste in the correct places.
 
##Click "Measure" when the alignment is correct. The board will be probed and the head will move to a second feature.
 
##Click "Measure" when the alignment is correct. The board will be probed and the head will move to a second feature.
##Repeat steps 9 and 10.
+
##Repeat steps 8 and 9.
##Click "Measure." The alignment is now finished. Click "Next."
+
##Click "Measure." The alignment is now finished.
##You can confirm the alignment by clicking various features and seeing if the head moves to the right position. If something is off, you can go back and realign if necessary.
+
##You can confirm the alignment by clicking various features and seeing if the head moves to the right position. If something is off, you can go back and realign if necessary. Proceed until you need to measure the height of the board.
##Click "Next."
+
##Click "Probe." This will measure the height of the board and determine how far away the dispenser needs to be from the board.
##Click "Probe." This will measure the height of the board.
+
##Once it finishes probing, remove the probe and replace it in the drawer.
##Remove the probe and replace it in the drawer. <br /> <br />
+
#'''Priming the Paste'''
#''Priming the Paste''
+
##Refer to the priming directions in step 8 before mounting the dispenser.
##'''Explain the priming process'''
+
##Once it is primed, mount it and proceed.
##Mount it. Click "Next."
 
 
##Click "Dispense." The paste will dispense onto all of the selected pads.
 
##Click "Dispense." The paste will dispense onto all of the selected pads.
##Strive for good coverage of paste. See the picture below.
+
##Strive for good coverage of paste, preferably covering most of the pad, if not all of it.
##Click "Next."
+
##Remove the dispenser. Twist the knob clockwise to back off the paste. '''Put it back in the fridge,''' and quit the Voltera app.
##Remove the dispenser. Twist the knob clockwise to back off the paste. '''Put it back in the fridge.''' Click '"Next."
+
##Unclamp the board from the Voltera. Remember that you are handling a board with wet paste. Clean up!
##Quit the Voltera app.
+
#'''Cleaning up'''
##Unclamp the board from the Voltera. Remember that you are handling a board with wet paste. <br /> <br />
+
##Clean any leftover paste or ink from the calibration switches by rubbing them with a dry cue tip before it dries.
#''Pick and Place Components''
+
##If any ink or paste remains elsewhere on the machine, use a cue tip or kimwipe with a little bit of isopropyl alcohol to clean it. Be careful not to drench the machine in isopropyl, as it could let gunk get into the machine and jam things up. [[File:Voltera cleaning.jpg|border|none|300x300px|Cleaning the calibration switches]]
##Clamp the board onto the Pick and Place.
 
##Power on the machine. The power switch is on the back.
 
##The arrow keys control the menu. These will be used to select things.
 
##Select "Place." Select "Manual."
 
##To move the turntable, select "Turntable," and use the arrow keys to move it clockwise or counterclockwise.
 
##The necessary components should be stocked in the slots in the turntable. If components are missing, contact any of the PCB lab staff.
 
##Turn on the Marshall monitor. This will help with viewing components.
 
##The Pick and Place is a like a vacuum machine. Its operation is straightforward.
 
###Move the gantry to the desired component. Press down (but not all the way) to stick the nozzle to the component.
 
###Move the gantry back to board. Move the component to its correct position so it appears to be close the pads. Lower the component about half a centimeter above the board.
 
###Turn the brake on with the arrow keys.
 
###Use the fine adjustment knobs at the bottom of the machine along with the monitor to perfectly align the component. Remember, you can swivel the camera in order to look down two different axes.
 
###When aligned, select "Place." The machine will automatically place the part to the position you set it to.
 
###Move the turntable to retrieve your next part.
 
###Repeat steps 1 through 6 until your board is complete.
 
##Remove your board from the clamps. '''Caution: Handle your board with care. Your components are not soldered and can easily dislodge from the paste!'''
 
##Turn off the Pick and Place machine.<br /> <br />
 
#''Reflow''.
 
##Power on the oven.
 
##Select "V1 Paste." The warm-up period is longer this time.
 
##Place your board in the oven. '''DANGER: THE RAILS ARE HOT.'''
 
##Select "Enter."
 
##Reflow takes about three minutes. When it's done, the drawer will automatically open to initiate the cool down phase. '''DANGER: The rails are HOT! DO NOT remove the board until the oven says all the stages are complete.''' The solder paste is actually solidifying.
 
##When the cool down process is done, remove the board. '''The rails are probably still hot!''' Select "Enter" to close the oven drawer.  
 
##Turn off the oven.<br /> <br />
 
#''Testing!''
 
##Take the board over to the power supply.
 
##Ensure to use '''the fixed''' '''5V''' connection on the power supply. Attach the positive and negative leads. Power on the PSU and press the button. The LED should illuminate! <br /><br />
 
Congrats! You're done. Got it all? Good. Why don't you go ahead and <u>take the quiz.</u>
 
<br />
 
  
== Dispensing Tips ==
+
You are now done with the PCB Printer! Refer to the Pick and Place as well as the Reflow Oven wikis for the remainder of the process.
  
=== The Perfect Print ===
+
==Debugging==
Two main factors affect the quality of your print.  
+
# First - Burnish the board very well. In order for the solder to adhere to the print traces, they need to be burnished.
 +
# Fixing unconnected traces - You can take the syringe of ink and manually draw new traces or touch up existing traces. Then, using the [[Rework_Station]] on max temperature, you can heat up the trace and get it to melt/adhere. This could take a few minutes, but it can be more effective than restarting or heading to the oven.  
  
==== Flow rate ====
+
==Safety==
  
==== Print height ====
+
#When the PCB Printer is moving and doing its thing, just let it be. Interfering will result in breaking equipment and possibly hurting yourself, especially with the drill. Voltera gives excellent advice/steps for their PCB fabrication process, be sure to follow them.
 +
#If you feel like you do not know what you are doing, ask someone for help. You could damage both the equipment and possibly hurt yourself. Do not hesitate to ask or confirm at any point during the process.
  
=== Priming Conductors ===
+
==Certification==
Ideally, ''you'' should never have to prime the conductors. After a conductor has been primed correctly and used in the Voltera, it "closes" the dispenser. When done, you should be able to pull it off the mount and put the --- back in the fridge.
+
Complete the <strong>PCB Lab - {{PAGENAME}} Module</strong> at the link below to gain access to the {{PAGENAME}}. The Maker Hub Canvas course pertains to all facilities and equipment contained in the Maker Hub; simply complete the quizzes for the facilities/equipment you wish to use in the Maker Hub. Please email <span style="color:blue">makerhub@georgefox.edu</span> if you have any questions.
  
However, this is not always the case. If a student
+
[https://georgefox.instructure.com/enroll/GH36RT Maker Hub Canvas Course]
<br />
 
  
== Installing a New Cartridge ==
+
==Troubleshooting==
  
# Remove the nozzle CAREFULLY
+
#Drilling
# Dissamble sheath by twisting green part clockwise
+
##If your holes seem to be all out of wack, be sure to confirm the following: you should be using the vacuum to suck up any debris that comes from drilling your board while it is drilling. The pieces can interfere with your part.
# Remove dispenser
+
##If they seem to be drilling in the wrong places, then it probably isn't aligned correctly. Go back in the process and start over.
# clean dispenser
+
#Calibration/Alignment
# press downwards on the sheath to loose the cartridge
+
##During the probing process, be sure that your board is completely flat and that the clamps cover a minimal amount of the board while keeping it secure. If the probing hits the claps or runs off the board, the calibration is no good. Go back to the initial stages where you align holes/indicate where to print traces.
# remove the cartridge
+
##When holes are available during the Alignment stage, always use them to align your board. NEVER use pads or traces unless you absolutely have to. Holes are much easier to align with.
# proceed to chuck the cartridge in the nearest garbage can
+
#Printing Traces/Solder
# wind the dispenser clockwise until it cant clockwise anymore
+
##Be sure that the dispenser has been warming up to room temperature for at least 15 minutes so the ink can flow smoothly.
# acquire new cartridge
+
##If the ink does not seem come come out even when you're priming the dispenser, chances are that it is clogged. Remove the tip, notify a PCB Lab worker, and install a new tip (ask a worker if you don't know how).
# remove top and bottom green caps SAVE THEM
 
# insert the cartidge with the label facing the back, in other words, the label should not be viewable through the window on the sheath
 
# insert the dispenser and lock it in by twisting the green part counter clockwise
 
# carefully REPLACE NOZZLE, use fingers first and then pliers!44
 
  
= Dev TODO =
+
==Maintenance==
* Change the gerber file to remove the solder paste on the lead pads<br /><br /><br /><br />
+
====General maintenance====
 +
The PCB Printer has a few items that need to be maintained by the student or the Ace. Refer to the table below to see each procedure, how often it should occur, and the the last completion of the specific task.
  
= References =
+
====Specific Maintenance Tasks====
<references />
+
{| class="wikitable"
 +
!Maintenance Procedure
 +
!Frequency
 +
!Done By
 +
!Last Completion
 +
|-
 +
|General Cleaning
 +
|Before and after each use, including ink/solder residue and drilled material
 +
|Student
 +
|N/A
 +
|-
 +
|Refrigerating the Dispensers
 +
|Whenever they are not in use
 +
|Student
 +
|N/A
 +
|-
 +
|Replacing Sacrificial Layer
 +
|When the existing layer is worn through and can potential damage the heating bed
 +
|Ace
 +
|
 +
|-
 +
|Replacing Nozzle
 +
|When the nozzle is clogged
 +
|Student or Ace
 +
|
 +
|-
 +
|Replacing ink/solder paste syringe
 +
|Whenever out of ink/solder paste
 +
|Ace
 +
| 01/27/2022 by MM
 +
|-
 +
|Labeling dispenser with lot name
 +
|Whenever ink/solder paste is replaced
 +
|Ace
 +
| 01/27/2022 by MM
 +
|-
 +
|Cleaning calibration switch linear hardware (Disassemble, clean, oil)
 +
|Once yearly, or as required.
 +
|Ace and Technician
 +
| 01/27/2022 by MM
 +
|}

Latest revision as of 10:11, 12 November 2024

Voltera Icon
The Voltera V-One PCB Printer

Make: Voltera

Model: V-One

Serial Number: V1-05-0129-120 / V1-04-0183-120

Ace: Isaac Beals (ibeals16@georgefox.edu).

Location: PCB Lab


Description

The PCB Printer (Voltera V-One) brings quick turn PCBs to your desktop. Import your Gerber file into the Voltera software, press print, and the V-One will bring your board to life. Use the drilling, solder paste dispensing, and reflow features to mount components onto your printed board, or mount components on a pre-fabricated board with ease.

This is a simple example of what the PCB Printer can do. Currently the PCB lab has a different baking process using a different oven, so we will be curing the boards using a different method than shown in the video.

Documentation

Terminology

The following conductive inks and pastes are stocked in the PCB Lab. Each material requires a special heating program setting. See each individual material below for the proper reflow oven setting.

Inks are also identified by a lot name and expiration date. If properly installed, the expiration date should be viewable through the window in the dispenser, but the lot name will not. Refer to the label on the back of the dispenser for the lot name. When selecting the ink you're using in the Voltera software, it will identify the ink by type, lot name, and expiration date. Make sure you select the correct one.

Voltera aqueous.PNG

Conductive Ink

- Use to lay conductive traces on substrates (Green is "V1 Ink" setting on Reflow Oven)


Voltera furious.PNG

Solder Paste

- Use only on boards that utilize Voltera's ink traces, such as the ink above. (Orange is "V1 Paste" setting on Reflow Oven)


Voltera armored.PNG

Solder Paste Sn63 Pb37

- Use only premade boards, such as ones from JLCPCB (Blue is "Sn63Pb37" on Reflow Oven)



Voltera User Manual

Circuit Design Guidelines

Altium Gerber Export Guide

Voltera Home Page

User Guides

Before you Print

Here are a few things to check before exporting your gerber files and fabricating your PCB.

Available drill bit sizes
  1. Verify via hole sizes.
    1. Based on the size of what needs to go in the via, select a rivet with the proper internal diameter from the table on the Through Hole Press page.
    2. Once you've selected the rivet size, take the outer diameter of the rivet from the table and add 0.1mm.
    3. Check this outer diameter against the available drill sizes for the Voltera (see the image to the right). Round up to the nearest drill size and use that for the hole size in Altium.
  2. Verify annular ring size
    1. Your annular rings (via diameter) should be at least as large as the head diameter of the rivets you plan to use, otherwise they might not make good contact.
  3. Check that your design follows the circuit design guidelines at the link above

Training

Operation

The PCB Printer is a fantastic tool for prototyping PCBs. After uploading Gerber files from Altium or a related software, the Voltera will be able to print traces and pads. The Voltera has the ability to bake traces and reflow components on its heated bed, but you will need to use the reflow oven to bake boards. The PCB Lab uses the reflow oven for baking due to the amount of people it needs to accommodate, so users will only be using the PCB Printer to print traces and pads. The Conductive Ink (used for Traces) is indicated by a green dot on the dispenser, the Voltera Solder Paste (used for Pads) is indicated by an orange dot on the dispenser, and the Manufactured Solder Paste (used for Pads) is indicated by a blue dot on the dispenser.

Before beginning with your PCB, it is imperative that it is completely flat, meaning no components are installed, as it will result in breaking the nozzle of the dispenser, or it will be unable to calibrate correctly.

Demonstration

To show a complete knowledge of the PCB Printer, the student will design a PCB in Altium or related software, print the traces/pads, and transition to the Reflow Oven. As a part of the process, the student will also perform correct set up and shut down procedures, all of which can be found in the General Procedure below.

General Procedure

Using the Voltera to create single-sided boards with NO vias or holes.

Training board - The Blinky 500
  1. Drilling
    1. This board in particular does not have any holes, so this entire step can be skipped for this procedure, however, these are the steps to take if you need to drill holes in the future.
    2. After opening the Voltera software, select Drill. This option is chosen only if you want to add holes to an existing board.
    3. For Drilling, you can either choose the Simple or Aligned route. Choose Simple if your board has no existing features, and choose Aligned if your board has some existing features. Lets go through the process for both.
    4. Drilling for a Simple Board
      1. Alrighty, you've chosen Simple, so this procedure assumes there is absolutely nothing fabricated on the board. Not gonna lie, this procedure is a little more sketchy than aligned simply because you literally eyeball your board's outline. The no eloquent calibration system. That's just how it works.
      2. Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
      3. Then it will ask you to move your boards location on the plate so the Voltera knows where it needs to drill. This is the sketchy part. It outlines a square, and you make a judgement based on what it thinks. If it outlines too low, move your circuit up further on the plate to compensate for it. If it outlines too far to the left, move your circuit to the right on the plate to compensate for it. Continue this process until it looks "good enough."
      4. Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication...
        Board.jpg
      5. Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.
        Voltera mount probe.jpg
      6. Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient. The transition between printing and drilling is done with the same alignment.
      7. Once that is complete, it is time to select the holes we want to drill. All the holes you select are highlighted in Green. Remove the probe and select which holes you want to drill. Remember not to drill the holes that already exist!
        ...holes.png
      8. Select the corresponding drill bit, put it into the drill, mount it, and plug it in. Be extra careful not to break anything. People usually break it because while they are mounting it, the drill hits the Voltera and snaps. It's okay to push it into the drill pretty far, and this will keep you from breaking it. DON'T FORGET TO USE THE ALLEN WRENCH TO SECURE THE BIT!
      9. The drill should sing you a little song once it's connected. Before drilling, prepare the vacuum. Use this to suck all the debris that comes from your board. You can get it decently close to the board, even on the board while it is drilling, just be sure to move when the drill is getting ready to move.
        VacuumBoi.jpg
      10. And you're finished drilling holes! Vacuum up any debris and continue with laying the traces.
    5. Drilling for an Aligned Board
      1. Awesome, you've chosen Aligned, so this procedure assumes you have some preexisting holes and the like on the board.
      2. Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
      3. Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication...
        Board.jpg
      4. Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.
        Voltera mount probe.jpg
      5. Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient.
      6. Once that is complete, it is time to select the holes we want to drill. All the holes you select are highlighted in Green. Anything that is highlighted in Green will be executed. Remove the probe and select which holes you want to drill. Remember not to drill the holes that already exist!
        ...holes.png
      7. Select the corresponding drill bit, put it into the drill, mount it, and plug it in. Be extra careful not to break anything. People usually break it because while they are mounting it, the drill hits the Voltera and snaps. It's okay to push it into the drill pretty far, and this will keep you from breaking it. DON'T FORGET TO USE THE ALLEN WRENCH TO SECURE THE BIT!
      8. The drill should sing you a little song once it's connected. Before drilling, prepare the vacuum. Use this to suck all the debris that comes from your board. You can get it decently close to the board, even on the board while it is drilling, just be sure to move when the drill is getting ready to move.
        VacuumBoi.jpg
      9. And you're finished drilling holes! Vacuum up any debris and continue with laying the traces.
  2. Ready the Ink
    1. The ink is most usable when it reaches room temperature, so we have to let it warm up in advance.
    2. Grab the correct conductive ink from the fridge, and let it warm up to room temperature, about 15-30 minutes. It is labeled with a green sticker.
  3. Software Setup
    1. Download the files for this project here.
    2. Power on the Voltera.
    3. Open the Voltera Windows application.
    4. Select "Print" and then "Simple." "Print" indicates that we want to print traces, and "Simple" indicates that the board is not pre-fabricated. If we had a pre-fabricated board, we would instead select "Aligned" so we can align the holes.
    5. Next we need to add the proper conductive ink, which is the same conductive ink you acquired in step 1.2.
    6. Load the ink file from the project files. This is the Top Layer Gerber file.
  4. Clamping the Substrate
    1. Acquire a 1.5" by 2" blank board. They are located in the one of the drawers.
    2. Slide the board underneath the clamps on the Voltera, push the clamps towards each other, and finger-tighten the thumb screws. You should not be able to move the board once you clamp them down.
      Voltera clamping.jpg
  5. Mounting the Probe
    1. Pull the probe from one of the drawers. The probe should have a large metal tip, do not confuse it with the dispenser.
      Voltera drawer.jpg
    2. Remove the cap and place it near the Voltera.
    3. Mount the probe onto the magnetic gantry. It should snap into place and the contacts should align.
      Voltera mount probe.jpg
  6. Positioning and Probing
    1. Click "Outline." This will show you where the Voltera thinks the board is. It will move the probe around the printer surface and determine how close the dispenser will need to be to the board.
    2. Repeat step one until the outline is centered with the board. Click and drag the circuit in the Voltera application to move the outline.
    3. You MUST ensure the outline does not collide with the clamps AND does not exceed the dimensions of the board! Do NOT proceed until this is checked!
    4. In the next step, Click "Probe" and wait for the Voltera to finish its measurements.
      Voltera probing.jpg
    5. Remove the probe, replace the cap, place the probe back in the drawer, and proceed.

  7. Priming the Conductor
    1. Ensure 15 minutes have passed before beginning the next step. This helps the ink flow easier, so the dispenser should not be cold to the touch.
    2. Read carefully. The Voltera application explains this step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings:
      - Nozzles are fragile! You would be surprised how easy it is to break one. Treat this process with care!
      - Hold the dispenser over a paper towel to prevent ink from getting everywhere.
      - If you need to wipe the nozzle, do so gently and use a cotton swab found in the drawers.
      - Ink should not be flowing quickly out of the dispenser when you finish priming, but a very small amount of flow is OK.
      Voltera priming.jpg
    3. Mount the dispenser.
      Voltera mount conductive.jpg
  8. Calibration
    1. Click "Advanced." Start with the Z at 0.10 mm and the E at 0 um. Adjust the Voltera to these values, as it is a safe distance for the dispenser.
    2. Click "Calibrate." The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink.
      Voltera calibrate.jpg
    3. The example below has slightly too much ink. Notice how a portion of the horizontal lines touch and some parts of the ink glob up.
      Voltera calibrate bad.jpg
    4. In this case, to make an adjustment, the ink height was set to a Z of 0.09 mm and the flow was set to an E of -10 um. This dispenses less ink than before.
    5. You may need to do the same or make different adjustments. Whatever you do, do NOT run the nozzle into the board! The nozzle will break!
    6. If an adjustment was made, wipe the board clean with a paper towel (shown below) and/or clean it with isopropyl alcohol and repeat the calibration.
      Voltera calibrate wipe.jpg
    7. The example below is a more acceptable test print. Strive for this consistency. If your board looks right, proceed.
      Voltera calibrate better.jpg
    8. Click "Next," and wipe the board clean a final time, as you are now preparing to print your whole circuit.

  9. Top Layer Print
    1. The Voltera will print what is selected in Green. Below is an example of a portion of the board selected. Ensure the portion you want to print is selected (in this case, select everything.) Remember that blue lines will not be printed.
      Voltera selection.PNG
    2. Click "Start." Let the Voltera finish its process. If a portion of the print fails or is incorrect, you can stop mid-print, or wait until it is finished and redo that selection. Also shown below is an example of a portion of ink that globbed up. The portion was wiped and can be reprinted.
      Voltera printing.jpg

      Voltera print blob.jpg

      Voltera print redo.jpg

    3. Remove the conductive ink, put the cap back on, and return the conductive ink to the fridge!
    4. When you reach the instruction titled "Flip Board," you are done. We want to bake these traces on the Reflow Oven before we do anything else to the board.
    5. Unclamp the board from the Voltera, and remember that the traces are still wet, so do not smear them around.
    6. Consult the Reflow Oven wiki and complete that process. Bake the board soon after printing to ensure best results.
  10. Preparing for Solder Paste
    1. You should now have a PCB with traces baked on it! Time to make those pads for placing components.
    2. Take a burnishing pad from one of the drawers. Rub the substrate with the pad until the traces have a shine to them, rather than a dull appearance. This cleans the surface of the traces and makes them look super shiny. AND IT IS CRITICALLY IMPORTANT!!! IF YOU DO NOT DO THIS, THE SOLDER HAS A VERY DIFFICULT TIME STICKING!!!!
    3. Replace the burnishing pad back into the drawer.
  11. Aligning the Paste
    1. This process will help the Voltera know where it needs to print solder. The user gives it two locations where the pads should go, and the Voltera can use the Gerber files to determine where else pads need to go.
    2. At this time, retrieve the solder paste from the fridge and set it out to warm. The correct paste is labeled with an orange sticker.
    3. Take the board back to the Voltera and clamp the board into place. Again, you should not be able to move the board after it is clamped.
    4. Open the Voltera application and choose "Solder," and choose the proper paste. In this case you want the orange-labeled paste.
    5. Clean the calibration switches, mount the probe, and proceed.
    6. Click 'Move to feature." This will move the probe to a pre-determined feature and should not be aligned properly on the first go. It is your job to align it correctly.
    7. First, use the arrow keys to roughly align the feature with the probe. This process will help the Voltera know where it needs to put the pads.
    8. Next, click "Lower," and use the arrow keys to fine-tune the alignment. Your precision in these steps is key to getting solder paste in the correct places.
    9. Click "Measure" when the alignment is correct. The board will be probed and the head will move to a second feature.
    10. Repeat steps 8 and 9.
    11. Click "Measure." The alignment is now finished.
    12. You can confirm the alignment by clicking various features and seeing if the head moves to the right position. If something is off, you can go back and realign if necessary. Proceed until you need to measure the height of the board.
    13. Click "Probe." This will measure the height of the board and determine how far away the dispenser needs to be from the board.
    14. Once it finishes probing, remove the probe and replace it in the drawer.
  12. Priming the Paste
    1. Refer to the priming directions in step 8 before mounting the dispenser.
    2. Once it is primed, mount it and proceed.
    3. Click "Dispense." The paste will dispense onto all of the selected pads.
    4. Strive for good coverage of paste, preferably covering most of the pad, if not all of it.
    5. Remove the dispenser. Twist the knob clockwise to back off the paste. Put it back in the fridge, and quit the Voltera app.
    6. Unclamp the board from the Voltera. Remember that you are handling a board with wet paste. Clean up!
  13. Cleaning up
    1. Clean any leftover paste or ink from the calibration switches by rubbing them with a dry cue tip before it dries.
    2. If any ink or paste remains elsewhere on the machine, use a cue tip or kimwipe with a little bit of isopropyl alcohol to clean it. Be careful not to drench the machine in isopropyl, as it could let gunk get into the machine and jam things up.
      Cleaning the calibration switches

You are now done with the PCB Printer! Refer to the Pick and Place as well as the Reflow Oven wikis for the remainder of the process.

Debugging

  1. First - Burnish the board very well. In order for the solder to adhere to the print traces, they need to be burnished.
  2. Fixing unconnected traces - You can take the syringe of ink and manually draw new traces or touch up existing traces. Then, using the Rework_Station on max temperature, you can heat up the trace and get it to melt/adhere. This could take a few minutes, but it can be more effective than restarting or heading to the oven.

Safety

  1. When the PCB Printer is moving and doing its thing, just let it be. Interfering will result in breaking equipment and possibly hurting yourself, especially with the drill. Voltera gives excellent advice/steps for their PCB fabrication process, be sure to follow them.
  2. If you feel like you do not know what you are doing, ask someone for help. You could damage both the equipment and possibly hurt yourself. Do not hesitate to ask or confirm at any point during the process.

Certification

Complete the PCB Lab - PCB Printer Module at the link below to gain access to the PCB Printer. The Maker Hub Canvas course pertains to all facilities and equipment contained in the Maker Hub; simply complete the quizzes for the facilities/equipment you wish to use in the Maker Hub. Please email makerhub@georgefox.edu if you have any questions.

Maker Hub Canvas Course

Troubleshooting

  1. Drilling
    1. If your holes seem to be all out of wack, be sure to confirm the following: you should be using the vacuum to suck up any debris that comes from drilling your board while it is drilling. The pieces can interfere with your part.
    2. If they seem to be drilling in the wrong places, then it probably isn't aligned correctly. Go back in the process and start over.
  2. Calibration/Alignment
    1. During the probing process, be sure that your board is completely flat and that the clamps cover a minimal amount of the board while keeping it secure. If the probing hits the claps or runs off the board, the calibration is no good. Go back to the initial stages where you align holes/indicate where to print traces.
    2. When holes are available during the Alignment stage, always use them to align your board. NEVER use pads or traces unless you absolutely have to. Holes are much easier to align with.
  3. Printing Traces/Solder
    1. Be sure that the dispenser has been warming up to room temperature for at least 15 minutes so the ink can flow smoothly.
    2. If the ink does not seem come come out even when you're priming the dispenser, chances are that it is clogged. Remove the tip, notify a PCB Lab worker, and install a new tip (ask a worker if you don't know how).

Maintenance

General maintenance

The PCB Printer has a few items that need to be maintained by the student or the Ace. Refer to the table below to see each procedure, how often it should occur, and the the last completion of the specific task.

Specific Maintenance Tasks

Maintenance Procedure Frequency Done By Last Completion
General Cleaning Before and after each use, including ink/solder residue and drilled material Student N/A
Refrigerating the Dispensers Whenever they are not in use Student N/A
Replacing Sacrificial Layer When the existing layer is worn through and can potential damage the heating bed Ace
Replacing Nozzle When the nozzle is clogged Student or Ace
Replacing ink/solder paste syringe Whenever out of ink/solder paste Ace 01/27/2022 by MM
Labeling dispenser with lot name Whenever ink/solder paste is replaced Ace 01/27/2022 by MM
Cleaning calibration switch linear hardware (Disassemble, clean, oil) Once yearly, or as required. Ace and Technician 01/27/2022 by MM