Line 106: Line 106:  
# ''Priming the Conductor''
 
# ''Priming the Conductor''
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
 
## Ensure 15 minutes have passed before beginning the next step. The dispenser should not be cold to the touch.
## '''Read carefully.''' The Voltera application explains this step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings: <br /><br /> - '''Nozzles are fragile!''' You would be surprised how easy it is to break one. <br /> - Hold the dispenser over a paper towel to prevent ink from getting everywhere.<br /> - If you need to wipe the nozzle, do so '''gently''' and '''use a cotton swab found in the drawers.''' <br /> - Ink should not be flowing quickly out of the dispenser when you finish priming, but '''a very small amount''' of flow is OK. [[File:Voltera priming.jpg|border|none|300x300px]] <br />
+
## '''Read carefully.''' The Voltera application explains this step well. Follow the on-screen instructions before moving on to the next step. Some tips/tricks/warnings: <br /><br /> - '''Nozzles are fragile!''' You would be surprised how easy it is to break one. <br /> - Hold the dispenser over a paper towel to prevent ink from getting everywhere.<br /> - If you need to wipe the nozzle, do so '''gently''' and '''use a cotton swab found in the drawers.''' <br /> - Ink should not be flowing quickly out of the dispenser when you finish priming, but '''a very small amount''' of flow is OK. <br /> [[File:Voltera priming.jpg|border|none|300x300px]] <br />
 
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
 
## Mount the dispenser. [[File:Voltera mount_conductive.jpg|border|none|300x300px]] <br />
 
# ''Calibration''
 
# ''Calibration''
## Click "Advanced." Start with the Z at 0.10 mm and the E at 0 um. Adjust the Voltera to these values.
+
## Click "Advanced." Start with the '''Z at 0.10 mm''' and the '''E at 0 um'''. Adjust the Voltera to these values.
 
## Click "Calibrate."
 
## Click "Calibrate."
 
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br />
 
## The Voltera will lay down a test print. Pay close attention to the amount and consistency of the ink. [[File:Voltera calibrate.jpg|border|none|300x300px]] <br />