Changes

Jump to navigation Jump to search
no edit summary
Line 5: Line 5:  
  |Is used in domain=Electronics
 
  |Is used in domain=Electronics
 
  |Has name={{PAGENAME}}
 
  |Has name={{PAGENAME}}
  |Has icon=File:laser_cutter_icon.png
+
|Has make=Trotec
 +
|Has model=Speedy 400
 +
|Has serial number=S4-2209 / 01422-11690
 +
|Has life expectancy=
 +
|Has year of manufacture or purchase=
 +
|Has replacement cost=
 +
  |Has icon=File:Speedy400_Laser.png
 
  |Has icondesc=Laser Engraver Icon
 
  |Has icondesc=Laser Engraver Icon
 
  |Has iconwname=File:laser_cutter_icon_name.png
 
  |Has iconwname=File:laser_cutter_icon_name.png
Line 12: Line 18:  
  |Has description=
 
  |Has description=
 
  |Has certification=https://georgefox.instructure.com/courses/1212
 
  |Has certification=https://georgefox.instructure.com/courses/1212
  |Has make=Trotec
+
  |Has view license key=0009999KWTSZCF9F
  |Has model=Speedy 400
+
  |Has activation license key=00099992K2C69A5B
|Has serial number=S4-2209 / 01422-11690
+
  |Has ace= Emily Hayes;ehayes19@georgefox.edu
  |Has ace= Zach Cogswell;zcogswell18@GeorgeFox.edu
   
}}
 
}}
 
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|140px|left|top|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
 
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|140px|left|top|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
Line 28: Line 33:     
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
 
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
 +
    
__TOC__
 
__TOC__
Line 42: Line 48:  
==Documentation==
 
==Documentation==
 
The Speedy 400 uses the same software and general setup as the Speedy 300, however it has a larger bed and a few backend setting differences. Should be able to train on either the 300 or 400 and use both machines.  
 
The Speedy 400 uses the same software and general setup as the Speedy 300, however it has a larger bed and a few backend setting differences. Should be able to train on either the 300 or 400 and use both machines.  
 
+
<!--
 
NOTE: Currently, the Speedy 400 should not be used for acrylic**. There are some issues with settings/airflow that cause acrylic to often catch fire while cutting (which, as you would imagine, is bad)
 
NOTE: Currently, the Speedy 400 should not be used for acrylic**. There are some issues with settings/airflow that cause acrylic to often catch fire while cutting (which, as you would imagine, is bad)
    
** If you know what you are doing and are very careful, small (<10 inches) pieces of 1/4" or 1/8" acrylic allow for sufficient airflow to avoid catching fire. Small pieces of 1/2" acrylic can often work as well, as long as you are careful. If the fumes light fire while cutting, pause the print IMMEDIATELY (the same button as start), or, if needed, stop it entirely (although this will abort the cut and you will not be able to continue). Often pausing allows the fire to go out and the acrylic to cool down, so for small cuts you may be able to continue, carefully, after pausing. If you must cut large sheets of acrylic, remove the paper from the area you are cutting, as close to the size of your cut as possible. Although it is not the paper that is burning, removing it seems to reduce the possibility of fire. Try not to remove any more paper than absolutely necessary, as the paper keeps the acrylic clean and protected from scratches when in the stock pile.
 
** If you know what you are doing and are very careful, small (<10 inches) pieces of 1/4" or 1/8" acrylic allow for sufficient airflow to avoid catching fire. Small pieces of 1/2" acrylic can often work as well, as long as you are careful. If the fumes light fire while cutting, pause the print IMMEDIATELY (the same button as start), or, if needed, stop it entirely (although this will abort the cut and you will not be able to continue). Often pausing allows the fire to go out and the acrylic to cool down, so for small cuts you may be able to continue, carefully, after pausing. If you must cut large sheets of acrylic, remove the paper from the area you are cutting, as close to the size of your cut as possible. Although it is not the paper that is burning, removing it seems to reduce the possibility of fire. Try not to remove any more paper than absolutely necessary, as the paper keeps the acrylic clean and protected from scratches when in the stock pile.
 +
-->
 +
 
====Terminology====
 
====Terminology====
   Line 62: Line 70:  
* Honeycomb Table - This is the honeycomb shaped metal tray that holds flat material during a cut. It is used for most cut jobs.   
 
* Honeycomb Table - This is the honeycomb shaped metal tray that holds flat material during a cut. It is used for most cut jobs.   
 
* Rotary Tool - When engraving water bottles or glasses, this accessory is used to hold the object in place as well as rotate it while performing a cut.
 
* Rotary Tool - When engraving water bottles or glasses, this accessory is used to hold the object in place as well as rotate it while performing a cut.
 +
 +
====Material Settings====
 +
 +
* '''[[Media:TrotecMaterials 2022.09.07 10.58.14.xml|Speedy 400 Material Settings 7 SEP 2022]]
    
====Manuals====
 
====Manuals====
 +
 
* '''[[Media:JobControl-Manual-EN.pdf|Job Control Operation Manual]]'''
 
* '''[[Media:JobControl-Manual-EN.pdf|Job Control Operation Manual]]'''
 
* '''[[Media:Speedy-400-Manual-EN.pdf|Speedy 400 Operation Manual]]'''
 
* '''[[Media:Speedy-400-Manual-EN.pdf|Speedy 400 Operation Manual]]'''
Line 171: Line 184:  
====General maintenance====
 
====General maintenance====
   −
To keep the laser cutter running and cutting smoothly, the mirror and lens should be periodically cleaned. This is on top of the general cleaning that should be done to keep the machine dust and scrap free. There is also filters in the exhaust system that must be changed once the activated carbon has been used up.
+
To keep the laser cutter running and cutting smoothly, the mirror and lens should be periodically cleaned. This is on top of the general cleaning that should be done to keep the machine dust and scrap free. There are also filters in the exhaust system that must be changed once the activated carbon has been used up.
    
====Specific Maintenance Tasks====
 
====Specific Maintenance Tasks====
Line 206: Line 219:  
|}
 
|}
 
# The honeycomb should be removed and the metal bed itself should be should be swept/cleaned more or less daily. Cleaners are available to help in this process. Green is general cleaning use this for the bed and metal surfaces. Blue is glass cleaner, use this for the plexiglass surfaces. The front door of the Speedy 300 may be removed using the spring loaded pin on the right to remove cut pieces stuck in the door. The air vents at the rear of the machine should be kept clean of debris. Clean in a manner similar to the bed.
 
# The honeycomb should be removed and the metal bed itself should be should be swept/cleaned more or less daily. Cleaners are available to help in this process. Green is general cleaning use this for the bed and metal surfaces. Blue is glass cleaner, use this for the plexiglass surfaces. The front door of the Speedy 300 may be removed using the spring loaded pin on the right to remove cut pieces stuck in the door. The air vents at the rear of the machine should be kept clean of debris. Clean in a manner similar to the bed.
# The lense, mirror, and cone should be inspected daily or more often as needed, especially after wood or other “dusty”/”smokey” materials are cut. The lense will need cleaning when particles are visible on the surface (hold up to light if need be). The lense may be removed using the threaded nut below the lense (see photo). The lense should be cleaned with the lense paper and cleaner available in the kit (lasercutter drawer) on both sides. Put some cleaner on the lense and gently rub the paper over the surface of the lense. The cone itself threads into the assembly below the lense nut. The cone may be cleaned with a paper towel and water or another cleaning agent. The mirror should be inspected and cleaned in the same manner as the lense.
+
# The lense, mirror, and cone should be inspected daily or more often as needed, especially after wood or other “dusty”/”smokey” materials are cut. The lense will need cleaning when particles are visible on the surface (hold up to light if need be). The lense may be removed using the threaded nut below the lense (see photo). First use the air bulb to blow any dust off of the lense, prior to cleaning with the lense paper and cleaner available in the kit (lasercutter drawer) on both sides. Put some cleaner on the lense and gently rub the paper over the surface of the lense. The cone itself threads into the assembly below the lense nut. The cone may be cleaned with a paper towel and water or another cleaning agent. The mirror should be inspected and cleaned in the same manner as the lense.
 
# See above.
 
# See above.
 
# The air filter to the right of the Speedy 300 will occasionally need maintenance. The most common issue is a full pre-filter. This will be indicated on the filter itself by poor airflow/suction. When replacing this, use a face mask and gloves (close the lab when doing this). Open the top of the air filter with the large 10mm hex wrench in the kit. Remove the prefilter and place it in a bag for disposal. Insert a new prefilter and close the lid. Pre-filters are used to increase the lifespan of other, harder to replace and more expensive filters in the system. Less often, other filters will need replacing. These include the larger box filter, additional pre-filter-type mat filters, and activated carbon. This should not need to happen as often. Follow the above procedure for pre-filter and the [https://www.youtube.com/watch?v=yJkCgAVbAEU&feature=youtu.be video] to replace the full filter setup. Be careful not to spill activate carbon if doing a full replacement, it is difficult to clean up.
 
# The air filter to the right of the Speedy 300 will occasionally need maintenance. The most common issue is a full pre-filter. This will be indicated on the filter itself by poor airflow/suction. When replacing this, use a face mask and gloves (close the lab when doing this). Open the top of the air filter with the large 10mm hex wrench in the kit. Remove the prefilter and place it in a bag for disposal. Insert a new prefilter and close the lid. Pre-filters are used to increase the lifespan of other, harder to replace and more expensive filters in the system. Less often, other filters will need replacing. These include the larger box filter, additional pre-filter-type mat filters, and activated carbon. This should not need to happen as often. Follow the above procedure for pre-filter and the [https://www.youtube.com/watch?v=yJkCgAVbAEU&feature=youtu.be video] to replace the full filter setup. Be careful not to spill activate carbon if doing a full replacement, it is difficult to clean up.