Changes

Jump to navigation Jump to search
Line 12: Line 12:  
   |Is used in domain=Electronics
 
   |Is used in domain=Electronics
 
   |Has function=Measurement
 
   |Has function=Measurement
   |Has icon=File:Electronics Workstation.png
+
   |Has icon=File:Electronics Workstation 2.png
 
   |Has icondesc=Oscilloscope graphic
 
   |Has icondesc=Oscilloscope graphic
   |Has image=File:Electronics Workstation.png
+
   |Has image=File:Electronics Workstation 2.png
 
   |Has imagedesc=Electronics Workstation
 
   |Has imagedesc=Electronics Workstation
 
   |Has description=Standard electronics measurement and signal generation equipment.
 
   |Has description=Standard electronics measurement and signal generation equipment.
Line 62: Line 62:     
==Function Generator==
 
==Function Generator==
 
+
[[File:Waveforms.png|400px|thumb|right|Different Waveform Shapes]]
 
A function generator creates AC periodic waveforms; it allows the user to manipulate an electrical signal’s amplitude, duty cycle, offset, and frequency over a wide range of values. This function generator can produce sine, square, triangle, ramp/sawtooth, and digital pulse waveforms. The manual for this function generator is fairly well-written, so I will only highlight a few excerpts here. I would encourage you to read the manual for complete operating instructions.
 
A function generator creates AC periodic waveforms; it allows the user to manipulate an electrical signal’s amplitude, duty cycle, offset, and frequency over a wide range of values. This function generator can produce sine, square, triangle, ramp/sawtooth, and digital pulse waveforms. The manual for this function generator is fairly well-written, so I will only highlight a few excerpts here. I would encourage you to read the manual for complete operating instructions.
[[File:Waveforms.png|400px|thumb|right|Different Waveform Shapes]]
      
===Controls===
 
===Controls===
 
+
[[File:FG Controls.jpg|400px|thumb|right|Function Generator Controls]]
 
There are eight range switches that select output frequencies from <1Hz to 10MHz. The coarse frequency knob adjusts the frequency within a range from 10%-of-the-maximum to the maximum. For example, if the 100kHz range is selected, the output frequency can be adjusted from 10kHz to 100kHz. The duty cycle, CMOS level, DC offset, and -20dB functions are only active if their corresponding switches are pressed in. The duty cycle knob alters the symmetry of the waveform through skewing or changing the ratio of “on” time versus “off” time. The DC offset changes the mean amplitude of the waveform. Reference the manual for information on more advanced capabilities such as the sweep functions, TTL/CMOS, and voltage-controlled generation.
 
There are eight range switches that select output frequencies from <1Hz to 10MHz. The coarse frequency knob adjusts the frequency within a range from 10%-of-the-maximum to the maximum. For example, if the 100kHz range is selected, the output frequency can be adjusted from 10kHz to 100kHz. The duty cycle, CMOS level, DC offset, and -20dB functions are only active if their corresponding switches are pressed in. The duty cycle knob alters the symmetry of the waveform through skewing or changing the ratio of “on” time versus “off” time. The DC offset changes the mean amplitude of the waveform. Reference the manual for information on more advanced capabilities such as the sweep functions, TTL/CMOS, and voltage-controlled generation.
 
The best way to “see” the output of a function generator is to use an oscilloscope. An oscilloscope will show you a graphical representation of the signal, and allow you to understand the effects of the waveform shape, frequency range switches, coarse/fine adjustment, duty cycle, DC offset, etc.
 
The best way to “see” the output of a function generator is to use an oscilloscope. An oscilloscope will show you a graphical representation of the signal, and allow you to understand the effects of the waveform shape, frequency range switches, coarse/fine adjustment, duty cycle, DC offset, etc.
Line 94: Line 93:     
One of the first things we need to understand about the oscilloscope is what it’s actually showing on the display screen. The display is set up like a standard Cartesian coordinate system. (you know, a graph...){{#evu:https://www.youtube.com/watch?v=sIlNIVXpIns|graph}}
 
One of the first things we need to understand about the oscilloscope is what it’s actually showing on the display screen. The display is set up like a standard Cartesian coordinate system. (you know, a graph...){{#evu:https://www.youtube.com/watch?v=sIlNIVXpIns|graph}}
 +
[[File:Oscilloscope Controls.jpg|400px|thumb|right|Oscilloscope Controls]]
 
The units of the graph tell us a lot about what we are looking at. The y-axis is voltage, and the x-axis is time. So, an oscilloscope will show—in real time—how a voltage signal is changing over time. One key skill we need to learn when using the oscilloscope is to manipulate the scales of the x-axis and y-axis so that you can see the voltage signal clearly and meaningfully on the oscilloscope’s display.
 
The units of the graph tell us a lot about what we are looking at. The y-axis is voltage, and the x-axis is time. So, an oscilloscope will show—in real time—how a voltage signal is changing over time. One key skill we need to learn when using the oscilloscope is to manipulate the scales of the x-axis and y-axis so that you can see the voltage signal clearly and meaningfully on the oscilloscope’s display.
 
There are 4 BNC jacks are on the bottom row of the oscilloscope’s control panel. Each one corresponds to channels 1, 2, 3, and 4. This is where you will plug in the probes that will measure various voltage signals in your circuit. Let’s discuss the knobs and buttons under the VERTICAL section of the control panel. For CH 1, the POSITION knob will move the signal on the display screen of the oscilloscope up and down the y-axis. This is handy when there is a DC voltage offset applied to the AC signal. The VOLTS/DIVISION knob will stretch or shrink the y-axis so that you can see the waveform’s amplitude properly. If the peaks or troughs of the waveform are hitting the top and/or bottom of the display screen, use the VOLTS/DIVISION knob to shrink the y-axis so that the full waveform can be seen. The CH 1 MENU button allows you to set up the probe properties and measurement displays for channel 1. The MATH MENU button allows you to perform operations between channels such as subtracting CH 2 from CH 1.
 
There are 4 BNC jacks are on the bottom row of the oscilloscope’s control panel. Each one corresponds to channels 1, 2, 3, and 4. This is where you will plug in the probes that will measure various voltage signals in your circuit. Let’s discuss the knobs and buttons under the VERTICAL section of the control panel. For CH 1, the POSITION knob will move the signal on the display screen of the oscilloscope up and down the y-axis. This is handy when there is a DC voltage offset applied to the AC signal. The VOLTS/DIVISION knob will stretch or shrink the y-axis so that you can see the waveform’s amplitude properly. If the peaks or troughs of the waveform are hitting the top and/or bottom of the display screen, use the VOLTS/DIVISION knob to shrink the y-axis so that the full waveform can be seen. The CH 1 MENU button allows you to set up the probe properties and measurement displays for channel 1. The MATH MENU button allows you to perform operations between channels such as subtracting CH 2 from CH 1.
Line 108: Line 108:     
==Digital Multimeter==
 
==Digital Multimeter==
 
+
[[File:DMM Controls.jpg|400px|thumb|right|Digital Multimeter Controls]]
 
A digital multimeter can measure a host of electrical properties including DC voltage and current, AC voltage and current, resistance, continuity, frequency, period, dB, dBm, True RMS AC+DC, and diode testing.
 
A digital multimeter can measure a host of electrical properties including DC voltage and current, AC voltage and current, resistance, continuity, frequency, period, dB, dBm, True RMS AC+DC, and diode testing.
   Line 142: Line 142:     
==Demonstration==
 
==Demonstration==
[[File:E W Circuit Diagram.jpg|400px|thumb|right|Demo Circuit Diagram]]
+
[[File:E W Circuit Pic.jpg|400px|thumb|right]][[File:Resistor-color-chart.png|400px|thumb|right]]
Set up a breadboard with a 10kΩ potentiometer as a voltage divider. Connect an LED's anode (the longer leg) to the wiper of the potentiometer. Connect a 560Ω resistor to the cathode (the shorter leg), and connect the other side of the resistor to ground. See the demo circuit diagram to the right for reference.
+
Set up a breadboard with a 10kΩ potentiometer as a voltage divider. Connect an LED's anode (the longer leg) to the wiper of the potentiometer. Connect a 560Ω resistor to the cathode (the shorter leg), and connect the other side of the resistor to ground. See the demo circuit diagram for reference.
 +
[[File:E W Circuit Diagram.jpg|400px|thumb|none|Demo Circuit Diagram]]
 +
Part 1: Connect a DC power supply to the input and set it to 10V. Slowly adjust the potentiometer to determine how much voltage and current is needed to turn on the LED. Measure the voltage and current using the digital multimeter.
   −
Part 1: Connect a DC power supply to the input and set it to 10V. Slowly adjust the potentiometer to determine how much voltage and current is needed to turn on the LED. Measure the voltage and current using the digital multimeter.
  −
[[File:E W Circuit Pic.jpg|400px|thumb|right]]
   
Part 2: Disconnect the DC power supply from the input and connect the function generator to the input. Connect the oscilloscope probes to both the input and output of the potentiometer to display the waveforms. Set the function generator to a sine wave to turn the LED on and off. Experiment with a DC offset and a square wave.
 
Part 2: Disconnect the DC power supply from the input and connect the function generator to the input. Connect the oscilloscope probes to both the input and output of the potentiometer to display the waveforms. Set the function generator to a sine wave to turn the LED on and off. Experiment with a DC offset and a square wave.
 
[[File:E W Oscilloscope Screen.jpg|400px|thumb|none|CH 1: Function generator signal to the input. CH 2: Output of the circuit measured at V2]]
 
[[File:E W Oscilloscope Screen.jpg|400px|thumb|none|CH 1: Function generator signal to the input. CH 2: Output of the circuit measured at V2]]
Line 153: Line 153:  
====User Manuals====
 
====User Manuals====
   −
[[Media:1651A DC Power Supply.pdf|1651A DC Power Supply Manual]]
+
[[Media:1651A DC Power Supply.pdf|1651A DC Power Supply User Manual]]
   −
[[Media:4017A Function Generator Manual.pdf|4017A Function Generator Manual]]
+
[[Media:4017A Function Generator Manual.pdf|4017A Function Generator User Manual]]
   −
[[Media:TDS 2024 Oscilloscope.pdf|TDS 2024 Oscilloscope Manual]]
+
[[Media:TDS 2024 Oscilloscope.pdf|TDS 2024 Oscilloscope User Manual]]
   −
[[Media:2831E Digital Multimeter Manual.pdf|2831E Digital Multimeter Manual]]
+
[[Media:2831E Digital Multimeter Manual.pdf|2831E Digital Multimeter User Manual]]
    
==Safety==
 
==Safety==

Navigation menu