Changes

Jump to navigation Jump to search
Line 4: Line 4:  
  |Is used in domain= Plastic
 
  |Is used in domain= Plastic
 
  |Has name={{PAGENAME}}
 
  |Has name={{PAGENAME}}
 +
|Has make=Artec
 +
|Has model=Spider & Eva
 +
|Has serial number=10.48856676 / 30.67367115
 +
|Has life expectancy=
 +
|Has year of manufacture or purchase=
 +
|Has replacement cost=
 
  |Has icon=File:3D_scannersIcon.png
 
  |Has icon=File:3D_scannersIcon.png
 
  |Has icondesc=
 
  |Has icondesc=
Line 10: Line 16:  
  |Has imagedesc= Artec Spider & Eva
 
  |Has imagedesc= Artec Spider & Eva
 
  |Has description=
 
  |Has description=
  |Has certification=
+
  |Has certification=https://georgefox.instructure.com/courses/1308
  |Has make=Artec
+
  |Has ace=Klayton Rhoads;krhoads16@georgefox.edu
|Has model=Eva & Spider
+
 
|Has ace=
   
}}
 
}}
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|100px|left|top|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
+
[[{{#show: {{FULLPAGENAME}}|?Has icon|link=none}}|140px|left|top|{{#show: {{FULLPAGENAME}}|?Has icondesc}}]]
 
[[{{#show: {{FULLPAGENAME}}|?Has image|link=none}}|375px|thumb|upright=1.5|{{#show: {{FULLPAGENAME}}|?Has imagedesc}}]]
 
[[{{#show: {{FULLPAGENAME}}|?Has image|link=none}}|375px|thumb|upright=1.5|{{#show: {{FULLPAGENAME}}|?Has imagedesc}}]]
   Line 21: Line 26:     
Model: {{#show: {{PAGENAME}} |?Has model}}
 
Model: {{#show: {{PAGENAME}} |?Has model}}
 +
 +
Serial Number: {{#show: {{PAGENAME}} |?Has serial number}}
    
Ace: {{#show: {{PAGENAME}} |?Has ace.Has name}} ({{#show: {{PAGENAME}} |?Has ace.Has email address}}).
 
Ace: {{#show: {{PAGENAME}} |?Has ace.Has name}} ({{#show: {{PAGENAME}} |?Has ace.Has email address}}).
    
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
 
Location: {{#show: {{PAGENAME}} |?Is located in facility}}
 +
    
==Description==
 
==Description==
Line 40: Line 48:  
Here is an example of this piece of equipment being used.
 
Here is an example of this piece of equipment being used.
   −
Insert video media here.
+
{{#evu:https://www.youtube.com/watch?v=KRxBuCYidsI}}
 +
 
 +
{{#evu:https://www.youtube.com/watch?v=wT2SRzSDEBo}}
    
==Documentation==
 
==Documentation==
Line 46: Line 56:  
====Terminology====
 
====Terminology====
   −
Insert terminology here
+
STL - A file format made up of surface geometry. This is a common file type for use with 3D printing. 
   −
User Manual
+
[[Media:Manual-15-EN.pdf|Artec Studio User Manual]]
https://www.artec3d.com/files/pdf/artec_studio_userguide_en.pdf
      
==Training==
 
==Training==
====Overview====
+
====Operation====
   −
Insert Text
+
The first step is to determine which scanner is correct for the job you will be doing.  The spider is normally used when you need more detail and are dealing with smaller objects as the EVA is better for larger projects.  When setting up the scanners you will need to connect the USB and power cord.  There are two videos provided to get you started using the software. Make sure to move the scanner in a slow pattern and keep your arm and wrist flexible rather than rigid. You will find it easier to control the scanner if you watch the computer screen rather than staring at the object being scanned. Using a turn table will help keep the scanner aligned with the object being scanned. You can flip the part over if needed to scan the underside.  The software does an amazing job of alignment.
    
====Demonstration====
 
====Demonstration====
   −
Insert text
+
Complete a scan of a small object like a Lego.
    
====General Procedure====
 
====General Procedure====
   −
Insert text
+
1. Choose which scanner you are going to use. The Spider can pick up more detail but has a small field of vision. Consequently, this is a good choice for smaller objects with many details. This scanner works best when it is held still while the object is rotated. When scanning larger objects like people this scanner is more difficult to use because of this field of vision. The Eva is not as detailed as the spider but is designed for larger objects and has a larger field of view. When scanning, it works well to walk around the object while scanning.
 +
 
 +
2. Plug the desired scanner into the computer and open the artec studios software.
 +
 
 +
3. Plug in scanner power and USB cables
 +
 
 +
4. Open Artec Studio
 +
 
 +
5. For Space Spider, wait for current temperature to reach optimal temperature range in order for accuracy to be at its best.
 +
 
 +
6. Press the rocker switch or slider up in order to enter preview mode
 +
 
 +
7. When scanning, make sure that the blue distance waveform is within the three green regions on the distance meter in order to get the best results.
 +
 
 +
[[File:Scan_Graph.jpg|none|thumb|600x600px]]
 +
 
 +
 
 +
8. Adjust texture brightness until detail is visible but colors are not blown out. This will need to be adjusted for each object scanned.
 +
 
 +
9. When scanning shiny or dark objects with the Space Spider, it may be necessary to adjust the sensitivity for the object to be scanned correctly. However, increasing the sensitivity will cause the scanner to capture more noise, increasing processing time. As a rule of thumb, don’t increase the sensitivity over 1/4 of the bar’s range. This step is not necessary with the Eva.
 +
 
 +
10. If speed is more important than accuracy, check the Real-time fusion box to make Artec Studio render the model in real time, removing the rendering step that is usually necessary after scanning.
 +
 
 +
11. For some objects, such as larger floorstanding objects, it may be helpful to check the Enable automatic base removal box in order to remove the base from the model during processing.
 +
 
 +
12. If scanning a smaller object, it is much easier to place the object on a turntable and scan it there.
 +
 
 +
13. Press the up button again to begin scanning the object.
 +
 
 +
14. While scanning, watch the computer screen to make sure that the distance from the scanner to the object is within the green range and that the object is at the center of the field of view.
 +
 
 +
15. Move the scanner all the way around the object with smooth motion, capturing as many different angles as possible. Once you have captured all you can with the object in its current position, press the down button on the scanner to stop, turn the object onto a different side, and repeat the scanning process.
 +
 
 +
16. Once you have captured enough angles, click on the Autopilot button on the left, select all the scans you would like to use, and adjust the scan quality values, following the in-software suggestions. Then click Next
 +
 
 +
17. If you did not select automatic base removal, or if there are extraneous objects that need to be removed, edit the object. Otherwise, skip the following step.
 +
 
 +
18. In the editing pane, select Cutoff-plane selection and draw on the base you would like to remove. Then, click next.
 +
 
 +
19. If alignment does not work properly, move the models next to each other and select several points, once on one model and once on the other, so that Artec Studio knows how to align the models.
 +
 
 +
20. Once alignment is complete, go to File/Export mesh and select the format to use for export.
    
==Safety==
 
==Safety==
Insert text
+
The scanners are very fragile.  Take care to prevent damage by dropping.  Never pull on the scanner cords as the connectors could be easily damaged. Keep your fingers off of the optical lens as the grease from your fingers can cause issues.
    
==Certification==
 
==Certification==
 +
Complete <strong>The Vault - {{PAGENAME}} Module</strong> at the link below to gain access to the {{PAGENAME}}. The Maker Hub Canvas course pertains to all facilities and equipment contained in the Maker Hub; simply complete the quizzes for the facilities/equipment you wish to use in the Maker Hub. Please email <span style="color:blue">makerhub@georgefox.edu</span> if you have any questions.
   −
Foxtale Quiz
+
[https://georgefox.instructure.com/enroll/G7CTPX Maker Hub Canvas Course]
    
==Troubleshooting==
 
==Troubleshooting==
Line 76: Line 127:  
====General maintenance====
 
====General maintenance====
   −
Insert text
+
Scanners should be wiped down with a dry cloth as needed.  Avoid touching lens windows.
    
====Specific Maintenance Tasks====
 
====Specific Maintenance Tasks====
Line 84: Line 135:  
!Done By
 
!Done By
 
|-
 
|-
|Sample
+
|N/A
|Sample
+
|N/A
|Sample
+
|N/A
 
|}
 
|}

Navigation menu