→‎General Procedure: Modified instructions on cleaning sensors to reflect current best practice of not using isopropyl, instead cleaning with dry q-tip when paste is still wet.
Line 117: Line 117:  
### Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
 
### Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
 
### Then it will ask you to move your boards location on the plate so the Voltera knows where it needs to drill. This is the sketchy part. It outlines a square, and you make a judgement based on what it thinks. If it outlines too low, move your circuit up further on the plate to compensate for it. If it outlines too far to the left, move your circuit to the right on the plate to compensate for it. Continue this process until it looks "good enough."
 
### Then it will ask you to move your boards location on the plate so the Voltera knows where it needs to drill. This is the sketchy part. It outlines a square, and you make a judgement based on what it thinks. If it outlines too low, move your circuit up further on the plate to compensate for it. If it outlines too far to the left, move your circuit to the right on the plate to compensate for it. Continue this process until it looks "good enough."
### Clean the calibration switches. Do not drench the Q-tip with Isopropyl alcohol, only get damp, and wipe away gently. Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication... [[File:Board.jpg|none|thumb|300x300px]]
+
### Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication... [[File:Board.jpg|none|thumb|300x300px]]
 
### Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
 
### Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
 
### Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient. The transition between printing and drilling is done with the same alignment.
 
### Once the alignment is complete, it will measure the height of every part of the board. It will take a couple minutes, so just be patient. The transition between printing and drilling is done with the same alignment.
Line 127: Line 127:  
### Awesome, you've chosen Aligned, so this procedure assumes you have some preexisting holes and the like on the board.
 
### Awesome, you've chosen Aligned, so this procedure assumes you have some preexisting holes and the like on the board.
 
### Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
 
### Voltera will ask you to upload your Ink and Hole files. Remember, the correct Hole file will say Plated in the name. This will allow you to calibrate the Voltera later and it supplies the drill locations.
### Clean the calibration switches. Do not drench the Q-tip with Isopropyl alcohol, only get damp, and wipe away gently.
   
### Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication...[[File:Board.jpg|none|thumb|300x300px]]
 
### Use the clamps and screws to secure your board. It would be such a shame if it moved during fabrication...[[File:Board.jpg|none|thumb|300x300px]]
 
### Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
 
### Mount the probe on machine. This will help us calibrate the machine. It will move to the wrong spot initially, but then it is your duty to move the probe into the correct spot. Lowering the probe will allow you to make fine tune movements to optimize the alignment.[[File:Voltera mount_probe.jpg|none|300x300px|thumb]]
Line 146: Line 145:  
## Next we need to add the proper conductive ink, which is the same conductive ink you acquired in step 1.2.
 
## Next we need to add the proper conductive ink, which is the same conductive ink you acquired in step 1.2.
 
## Load the ink file from the project files. This is the Top Layer Gerber file.  
 
## Load the ink file from the project files. This is the Top Layer Gerber file.  
# '''Cleaning the Sensors'''
  −
## Take a cue tip and dip it into the isopropyl alcohol. The cue tip should be moist, but NOT soaked. Dab the cue tip on a paper towel to dry it slightly.
  −
## Clean the calibration switches by rubbing them with the cue tip.This will help clear out any crap that could hurt the sensor. [[File:Voltera cleaning.jpg|border|none|300x300px|Cleaning the calibration switches]]
   
# '''Clamping the Substrate'''
 
# '''Clamping the Substrate'''
 
## Acquire a 1.5" by 2" blank board. They are located in the one of the drawers.
 
## Acquire a 1.5" by 2" blank board. They are located in the one of the drawers.
Line 208: Line 204:  
##Remove the dispenser. Twist the knob clockwise to back off the paste. '''Put it back in the fridge,''' and quit the Voltera app.
 
##Remove the dispenser. Twist the knob clockwise to back off the paste. '''Put it back in the fridge,''' and quit the Voltera app.
 
##Unclamp the board from the Voltera. Remember that you are handling a board with wet paste. Clean up!
 
##Unclamp the board from the Voltera. Remember that you are handling a board with wet paste. Clean up!
##You are now done with the PCB Printer! Refer to the Pick and Place as well as the Reflow Oven wikis for the remainder of the process
+
# '''Cleaning up'''
# '''18658 [what is this?]'''
+
## Clean any leftover paste or ink from the calibration switches by rubbing them with a dry cue tip before it dries.
## The board consists of a button, a 680Ω resistor, and an LED. Attach a fixed 5VDC connection to the + and -, and the LED should illuminate.
+
## If any ink or paste remains elsewhere on the machine, use a cue tip or kimwipe with a little bit of isopropyl alcohol to clean it. Be careful not to drench the machine in isopropyl, as it could let gunk get into the machine and jam things up. [[File:Voltera cleaning.jpg|border|none|300x300px|Cleaning the calibration switches]]
 +
 
 +
You are now done with the PCB Printer! Refer to the Pick and Place as well as the Reflow Oven wikis for the remainder of the process.
    